| Availability: | |
|---|---|
GA6248MH
Techfine
Feature
Communication Option: External WIFl, Supervise at Any Time
Support Working without Battery: Reduce Solar System Cost
Parallel Function Up to Maximum 9 Units: Enlarge More Loads
High Precision of Output Voltage,+5%, Take Care of YourAppliances
Battery Reverse Connection Protection with Fuse SwitchSafer Installation
Lithium Battery Auto-restart Function,More Convenientfor Lithium Battery Charging
Intelligent Power Supply Mode,Intelligent Distribution of Solal Panel/Mains/BatteryPower Shares

Feature
Communication Option: External WIFl, Supervise at Any Time
Support Working without Battery: Reduce Solar System Cost
Parallel Function Up to Maximum 9 Units: Enlarge More Loads
High Precision of Output Voltage,+5%, Take Care of YourAppliances
Battery Reverse Connection Protection with Fuse SwitchSafer Installation
Lithium Battery Auto-restart Function,More Convenientfor Lithium Battery Charging
Intelligent Power Supply Mode,Intelligent Distribution of Solal Panel/Mains/BatteryPower Shares

| Model | GB10048MH | ||
| Input | Input Sources | L+N+PE | |
| Rated Input Voltage | 220/230/240VAC | ||
| Voltage Range | 90-280VAC+3V(APL Mode)170-280VAC+3V(UPS Mode) | ||
| Freqency | 50Hz/60Hz(Auto Ad aptive) | ||
| Output | Rated Capacity | 10000W | |
| Output Voltage | 220/230/240VAC+5% | ||
| Output Frequency | 50/60Hz+0.1% | ||
| Waveform | Pure Sine Wave | ||
| Transfer Time(adjustable) | Computers(U PS Mode)1 Oms, Appliance(APL Mode )20ms | ||
| Peak Power | 20000VA | ||
| Over Load Ability | Battery Mode: 10.5s@11 0% 150%Load;5.5s@150% 200% Load;200ms @>200%Load | ||
| Peak Efficiency (Battery Mode) | >94% | ||
| Battery | Battery Votage | 48Vdc | |
| Constant Charging Voltage (Adjustable) | 56.4Vdc | ||
| Flotage Charging Voltage (Adjustable) | 54Vdc | ||
| Chargers | PV Charging Mode | MPPT Dual MPPT | |
| MAX.PV Input Power | 2* 5500W | ||
| MPPT Tracking Range | 120-500Vdc | ||
| Best Voltage | 300-400V | ||
| MAX.PV Input Vlotage | 500Vdc | ||
| MAX.PV Charging Current | 160A | ||
| MAX.AC Charging Current | 120A | ||
| MAX.Charging Current | 160A | ||
| Dispaly | LCD Display | Display Running Mode/Loads/Input/Output etc. | |
| Interface | RS232 | 5PIN/Pitch2.0mm. Baud Rate2400 | |
| Communication Port | 2x 5PIN/Pitch2.54mm,Lithium Lattery BMS Communication Card, WifiCard ,DryContact | ||
| Parallel Connect Interface | With Parallel | ||
| Environments | Operating Temperature | 0-40°C | |
| Humidity | 20%-95%(Non-condensing) | ||
| Storage Temperature | -15~60℃ | ||
| Altitude | Altiude Not Over 1000m,Derating over 1000m,Max 4000m. Refer to IEC62040 | ||
| Noise | ≤50db | ||
| Model | GB10048MH | ||
| Input | Input Sources | L+N+PE | |
| Rated Input Voltage | 220/230/240VAC | ||
| Voltage Range | 90-280VAC+3V(APL Mode)170-280VAC+3V(UPS Mode) | ||
| Freqency | 50Hz/60Hz(Auto Ad aptive) | ||
| Output | Rated Capacity | 10000W | |
| Output Voltage | 220/230/240VAC+5% | ||
| Output Frequency | 50/60Hz+0.1% | ||
| Waveform | Pure Sine Wave | ||
| Transfer Time(adjustable) | Computers(U PS Mode)1 Oms, Appliance(APL Mode )20ms | ||
| Peak Power | 20000VA | ||
| Over Load Ability | Battery Mode: 10.5s@11 0% 150%Load;5.5s@150% 200% Load;200ms @>200%Load | ||
| Peak Efficiency (Battery Mode) | >94% | ||
| Battery | Battery Votage | 48Vdc | |
| Constant Charging Voltage (Adjustable) | 56.4Vdc | ||
| Flotage Charging Voltage (Adjustable) | 54Vdc | ||
| Chargers | PV Charging Mode | MPPT Dual MPPT | |
| MAX.PV Input Power | 2* 5500W | ||
| MPPT Tracking Range | 120-500Vdc | ||
| Best Voltage | 300-400V | ||
| MAX.PV Input Vlotage | 500Vdc | ||
| MAX.PV Charging Current | 160A | ||
| MAX.AC Charging Current | 120A | ||
| MAX.Charging Current | 160A | ||
| Dispaly | LCD Display | Display Running Mode/Loads/Input/Output etc. | |
| Interface | RS232 | 5PIN/Pitch2.0mm. Baud Rate2400 | |
| Communication Port | 2x 5PIN/Pitch2.54mm,Lithium Lattery BMS Communication Card, WifiCard ,DryContact | ||
| Parallel Connect Interface | With Parallel | ||
| Environments | Operating Temperature | 0-40°C | |
| Humidity | 20%-95%(Non-condensing) | ||
| Storage Temperature | -15~60℃ | ||
| Altitude | Altiude Not Over 1000m,Derating over 1000m,Max 4000m. Refer to IEC62040 | ||
| Noise | ≤50db | ||