Availability: | |
---|---|
CYE2K
Techfine
* Long back up design, able to last 24 hours.* Adopt CPU design, computer interface, have self detection function.
* With three-level lightning protection, multi protection of your equipment.
* High Standard Level 3 Lightning Protection Ensure Your Equipments Under Fully Protect.
1. Departmental servers
2. Small LAN
3. Workstation
4. IPO
5. Small medical devices
6. Small precision electronic instruments
7. Enterprise Server
8. Enterprise Lan
9. High-end servers
10. Network Equipment
11. Data center room
12. Sophisticated electronic equipment
* Long back up design, able to last 24 hours.* Adopt CPU design, computer interface, have self detection function.
* With three-level lightning protection, multi protection of your equipment.
* High Standard Level 3 Lightning Protection Ensure Your Equipments Under Fully Protect.
1. Departmental servers
2. Small LAN
3. Workstation
4. IPO
5. Small medical devices
6. Small precision electronic instruments
7. Enterprise Server
8. Enterprise Lan
9. High-end servers
10. Network Equipment
11. Data center room
12. Sophisticated electronic equipment
Factory model | CYE2K (S) |
phase | Single phase |
capacity | 2000 VA / 1600 W |
Input | |
Voltage range | 145 -280VAC |
Frequency range | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Power factor | At 100% load ≧0.98 |
Output | |
Output voltage | 220VAC±10% |
Voltage range (battery mode) | ± 2% (±10% mains mode) |
Frequency range (synchronous correction range) | 47~ 53 Hz or 57 ~ 63 Hz |
Frequency range (battery mode) | 50 Hz ± 0.25 Hz |
Surge ratio | 3:1 |
Harmonic distortion | ≦ 3% THD (Linear load) ≦6% THD (nonlinear load) |
Conversion time | ≤8ms |
Wave form | Pure sine wave |
Battery | |
Standard battery model | 12V / 7AH |
quantity | 4or6 |
Maximum charging current | 1.5A(Max) |
Charging voltage | 55\82.1VDC ± 1% |
Long-lasting machine battery model | Depends on applicant |
quantity | 6 |
Maximum charging current | 6A(adjustable) |
Charging voltage | 82.1VDC ± 1% |
Appearance | |
LCD or LED display | Load size, battery capacity, mains mode, Battery mode, bypass mode, fault indication |
Alarm | |
Battery mode | It goes off every four seconds |
Low battery | It goes off every second |
Over duty | It goes off every second |
mistake | Continuous ringing |
Overall dimension | |
Marking machine dimensions, D x W x H (mm) | 450x192x335 |
Net weight (kg) | 25.3\29.7 |
Long life machine size, D x W x H (mm) | 350x192x335 |
Net weight (kg) | 15.97 |
Use environment | |
Temperature and humidity | Relative humidity 20-90% and temperature 0-40 °C (no condensation) |
noise | Less than 45DB@1 m |
Control management | |
Smart RS-232/ USB | Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, |
Optional SNMP | Power management Supports SNMP management and network management |
Added performance features with B-ultrasound (model suffix plus B for B-ultrasound) | |
Low leakage current | The leakage current of the whole machine is < 500uA |
Electromagnetic compatibility | No interference to medical B-ultrasound equipment |
noise | Less than 40dBA@ 1 m |
Factory model | CYE2K (S) |
phase | Single phase |
capacity | 2000 VA / 1600 W |
Input | |
Voltage range | 145 -280VAC |
Frequency range | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Power factor | At 100% load ≧0.98 |
Output | |
Output voltage | 220VAC±10% |
Voltage range (battery mode) | ± 2% (±10% mains mode) |
Frequency range (synchronous correction range) | 47~ 53 Hz or 57 ~ 63 Hz |
Frequency range (battery mode) | 50 Hz ± 0.25 Hz |
Surge ratio | 3:1 |
Harmonic distortion | ≦ 3% THD (Linear load) ≦6% THD (nonlinear load) |
Conversion time | ≤8ms |
Wave form | Pure sine wave |
Battery | |
Standard battery model | 12V / 7AH |
quantity | 4or6 |
Maximum charging current | 1.5A(Max) |
Charging voltage | 55\82.1VDC ± 1% |
Long-lasting machine battery model | Depends on applicant |
quantity | 6 |
Maximum charging current | 6A(adjustable) |
Charging voltage | 82.1VDC ± 1% |
Appearance | |
LCD or LED display | Load size, battery capacity, mains mode, Battery mode, bypass mode, fault indication |
Alarm | |
Battery mode | It goes off every four seconds |
Low battery | It goes off every second |
Over duty | It goes off every second |
mistake | Continuous ringing |
Overall dimension | |
Marking machine dimensions, D x W x H (mm) | 450x192x335 |
Net weight (kg) | 25.3\29.7 |
Long life machine size, D x W x H (mm) | 350x192x335 |
Net weight (kg) | 15.97 |
Use environment | |
Temperature and humidity | Relative humidity 20-90% and temperature 0-40 °C (no condensation) |
noise | Less than 45DB@1 m |
Control management | |
Smart RS-232/ USB | Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, |
Optional SNMP | Power management Supports SNMP management and network management |
Added performance features with B-ultrasound (model suffix plus B for B-ultrasound) | |
Low leakage current | The leakage current of the whole machine is < 500uA |
Electromagnetic compatibility | No interference to medical B-ultrasound equipment |
noise | Less than 40dBA@ 1 m |