| Availability: | |
|---|---|
CYE1K
Techfine
* Long back up design, able to last 24 hours.* Adopt CPU design, computer interface, have self detection function.
* With three-level lightning protection, multi protection of your equipment.
* High Standard Level 3 Lightning Protection Ensure Your Equipments Under Fully Protect.

* Long back up design, able to last 24 hours.* Adopt CPU design, computer interface, have self detection function.
* With three-level lightning protection, multi protection of your equipment.
* High Standard Level 3 Lightning Protection Ensure Your Equipments Under Fully Protect.

| Factory model | CYE1K (S) |
| phase | Single phase |
| capacity | 1000 VA / 800 W |
| Input | |
| Voltage range | 145 -280VAC |
| Frequency range | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
| Power factor | At 100% load ≧0.98 |
| Output | |
| Output voltage | 220VAC±10% |
| Voltage range (battery mode) | ± 2% (±10% mains mode) |
| Frequency range (synchronous correction range) | 47~ 53 Hz or 57 ~ 63 Hz |
| Frequency range (battery mode) | 50 Hz ± 0.25 Hz |
| Surge ratio | 3:1 |
| Harmonic distortion | ≦ 3% THD (Linear load) ≦6% THD (nonlinear load) |
| Conversion time | ≤8ms |
| Wave form | Pure sine wave |
| Battery | |
| Standard battery model | 12V / 7AH |
| quantity | 2 |
| Maximum charging current | 1.5A(Max) |
| Charging voltage | 27.5VDC ± 1% |
| Long-lasting machine battery model | Depends on applicant |
| quantity | 3 |
| Maximum charging current | 6A(adjustable) |
| Charging voltage | 41.0VDC ± 1% |
| Appearance | |
| LCD or LED display | Load size, battery capacity, mains mode, Battery mode, bypass mode, fault indication |
| Alarm | |
| Battery mode | It goes off every four seconds |
| Low battery | It goes off every second |
| Over duty | It goes off every second |
| mistake | Continuous ringing |
| Overall dimension | |
| Marking machine dimensions, D x W x H (mm) | 352x145x213 |
| Net weight (kg) | 12.96 |
| Long life machine size, D x W x H (mm) | 352x145x213 |
| Net weight (kg) | 9.54 |
| Use environment | |
| Temperature and humidity | Relative humidity 20-90% and temperature 0-40 °C (no condensation) |
| noise | Less than 45DB@1 m |
| Control management | |
| Smart RS-232/ USB | Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, |
| Optional SNMP | Power management Supports SNMP management and network management |
| Added performance features with B-ultrasound (model suffix plus B for B-ultrasound) | |
| Low leakage current | The leakage current of the whole machine is < 500uA |
| Electromagnetic compatibility | No interference to medical B-ultrasound equipment |
| noise | Less than 40dBA@ 1 m |
| Factory model | CYE1K (S) |
| phase | Single phase |
| capacity | 1000 VA / 800 W |
| Input | |
| Voltage range | 145 -280VAC |
| Frequency range | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
| Power factor | At 100% load ≧0.98 |
| Output | |
| Output voltage | 220VAC±10% |
| Voltage range (battery mode) | ± 2% (±10% mains mode) |
| Frequency range (synchronous correction range) | 47~ 53 Hz or 57 ~ 63 Hz |
| Frequency range (battery mode) | 50 Hz ± 0.25 Hz |
| Surge ratio | 3:1 |
| Harmonic distortion | ≦ 3% THD (Linear load) ≦6% THD (nonlinear load) |
| Conversion time | ≤8ms |
| Wave form | Pure sine wave |
| Battery | |
| Standard battery model | 12V / 7AH |
| quantity | 2 |
| Maximum charging current | 1.5A(Max) |
| Charging voltage | 27.5VDC ± 1% |
| Long-lasting machine battery model | Depends on applicant |
| quantity | 3 |
| Maximum charging current | 6A(adjustable) |
| Charging voltage | 41.0VDC ± 1% |
| Appearance | |
| LCD or LED display | Load size, battery capacity, mains mode, Battery mode, bypass mode, fault indication |
| Alarm | |
| Battery mode | It goes off every four seconds |
| Low battery | It goes off every second |
| Over duty | It goes off every second |
| mistake | Continuous ringing |
| Overall dimension | |
| Marking machine dimensions, D x W x H (mm) | 352x145x213 |
| Net weight (kg) | 12.96 |
| Long life machine size, D x W x H (mm) | 352x145x213 |
| Net weight (kg) | 9.54 |
| Use environment | |
| Temperature and humidity | Relative humidity 20-90% and temperature 0-40 °C (no condensation) |
| noise | Less than 45DB@1 m |
| Control management | |
| Smart RS-232/ USB | Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, |
| Optional SNMP | Power management Supports SNMP management and network management |
| Added performance features with B-ultrasound (model suffix plus B for B-ultrasound) | |
| Low leakage current | The leakage current of the whole machine is < 500uA |
| Electromagnetic compatibility | No interference to medical B-ultrasound equipment |
| noise | Less than 40dBA@ 1 m |